DB30 UV-Vis Spectrophotometer
DB30 double beam UV-Vis spectrophotometer, 190–1100 nm
LabVibe Solutions supplies the DB30 UV-Vis Spectrophotometer to universities, IITs, research institutes and industrial laboratories across India from our office in Bangalore. We help you choose the right model for your application, and provide a quotation, delivery, installation, training, warranty support and product demonstrations.
About the DB30 UV-Vis Spectrophotometer
The DB30 is a double beam UV-Vis spectrophotometer. It measures absorbance and transmittance from 190 to 1100 nm, using deuterium and tungsten-halogen lamps, a Czerny-Turner monochromator and a silicon photodiode detector. Five selectable bandwidths from 0.5 to 4 nm and scan speeds of up to 6,000 nm/min suit both high-resolution work and fast routine testing.
Every DB30 comes with a 7-inch touchscreen, so it can run as a standalone instrument for wavelength scans, kinetics, multi-wavelength photometry and quantitation, with built-in protein, nucleic acid and hexavalent chromium methods. Results can be saved to internal memory, a USB drive or an SD card. Optional PC software is available, including a version that supports FDA 21 CFR Part 11 compliance with user logins, e-signatures and an audit trail.
A range of accessories extends the DB30 to micro-volume cells, long path cells, films, glass filters, temperature-controlled measurements and automatic sampling. New NanoSize and NanoIndex packages add nanophotonic cuvettes and cloud-based analysis, so the DB30 can also estimate nanoparticle size and measure refractive index.
LabVibe Solutions supplies scientific instruments across India from Bangalore. We supply the DB30 to universities, IITs, research institutes, pharmaceutical and industrial laboratories across the country, with on-site installation, user training, warranty support and product demonstrations.
Applications
Where the DB30 UV-Vis Spectrophotometer is used
Pharmaceutical
- •Assay and dissolution testing
- •Pharmacopoeia performance checks
- •Impurity and stability studies
Life sciences
- •DNA, RNA and protein quantification
- •Enzyme kinetics
- •Cell culture and microbiology (OD600)
Chemistry & materials
- •Band gap of semiconductors and nanomaterials
- •Concentration and calibration curves
- •Thin-film transmittance
Environment & food
- •Water and wastewater analysis (nitrate, phosphate, COD)
- •Colour and dye analysis
- •Food and beverage QC
Key features
- ✓Double beam, Czerny-Turner monochromator
- ✓Wavelength range 190–1100 nm
- ✓Variable bandwidth 0.5, 1, 1.5, 2 and 4 nm
- ✓Scan speed up to 6,000 nm/min
- ✓7-inch touchscreen for standalone use
- ✓Optional 21 CFR Part 11 compliant software
DB30 UV-Vis Spectrophotometer specifications
| Optics | Czerny-Turner, double beam monochromator |
|---|---|
| Wavelength range | 190–1,100 nm |
| Spectral bandwidth | 0.5, 1, 1.5, 2 and 4 nm |
| Stray light | ≤1% (198 nm KCl), ≤0.05% (220 nm NaI, 340 nm NaNO2) |
| Wavelength accuracy | ±0.1 nm at D2 peak 656.1 nm, ±0.25 nm over entire range |
| Wavelength repeatability | ≤0.1 nm (max deviation), ≤0.05 nm (standard deviation) |
| Photometric range | Absorbance −3.4 to +3.4; %T 0 to 300; concentration 0.000 to 9,999 |
| Photometric accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.008 Abs (1.0–2.0 Abs), ±0.3 %T |
| Photometric reproducibility | ±0.0005 Abs (0.5 Abs), ±0.001 Abs (1.0 Abs), ±0.004 Abs (2.0 Abs) |
| Scan speed | 10, 100, 200, 400, 800, 1200, 2400, 3600, 6000 nm/min |
| Noise | 0.0001 Abs (peak-to-peak), 0.00005 Abs (RMS) |
| Baseline stability | 0.0003 Abs/hr (500 nm, after 2 hour lamp warm-up) |
| Baseline flatness | ±0.0009 Abs (200–950 nm) |
| Light source | Tungsten-halogen and deuterium lamps |
| Lamp switching | Automatic, selectable between 325 and 370 nm |
| Detector | Silicon photodiode |
| Display | 7-inch touchscreen |
| Software | Touchscreen operation, PC control software, or 21 CFR Part 11 compliant PC software |
| Data output | Internal memory, USB flash drive, SD card; USB PC interface |
| Dimensions (W × D × H) | 500 × 475 × 250 mm |
| Weight | Approx. 20 kg |
| Power supply | 100–240 V, 50–60 Hz |
| Operating temperature | 10–35 °C |
| In the box | DB30 unit, operation manual, 2 quartz cuvettes |
| Manufacturer warranty | 1 year from date of delivery (under normal maintenance) |
DB30 UV-Vis Spectrophotometer accessories

6-position cell holder
Up to six 10 mm cells with automatic changeover

Micro cell holder
For 50 µl micro-volume cells

Micro flow cell
70 µl flow cell, 10 mm path, for continuous measurement

Long path cell holder
Two rectangular cells with 10–100 mm path length

Thermostatic cell holder
Room temperature to +40 °C, stability ±0.3 °C

Electronic temperature-controlled holder
15–110 °C with built-in stirring

Film holder
Thin-film samples up to 25 × 50 mm

Glass filter holder
Glass samples and filters up to 55 × 100 mm, 5 mm thick

Auto sipper
Automatic sampling of many liquid samples without changing cells

SpectroLink
Advanced measurements such as particle size and refractive index
Standard cell holder
Two positions for standard 10 mm cells
Installation, training, warranty and demo
Installation
On-site installation and setup by our team.
Training
Hands-on training for your users on the instrument and software.
Warranty
Warranty support and after-sales service across India.
Demo
Product demonstrations on request before you buy.
Buy the DB30 UV-Vis Spectrophotometer from LabVibe Solutions
Trusted by laboratories at IITs, IISc, NITs and ISRO centres. Send us your requirements and we will recommend a suitable configuration and share a quotation, including for tender purchases.
Get a quotationRequest a quote for the DB30 UV-Vis Spectrophotometer
Tell us what you need and we will reply with a quotation, usually within one working day.
Frequently asked questions
What is the wavelength range of the DB30?
The DB30 covers 190–1100 nm, with selectable bandwidths of 0.5, 1, 1.5, 2 and 4 nm.
Can the DB30 be used without a computer?
Yes. Every DB30 has a 7-inch touchscreen for standalone measurement, analysis and data storage. PC software is optional.
Is 21 CFR Part 11 compliance available?
Yes. A compliant PC software package is available as an option, with secure user logins, e-signatures and audit trail logging.
Can the DB30 measure particle size?
Yes, with the DB30 NanoSize package. The NanoIndex package adds refractive index and micro-volume measurements.
What is the price of the DB30 in India?
The price depends on the configuration, software and accessories you need. Contact us with your requirements and we will send a quotation.